  features din rail series ? universal ac input (85-264vac) ? protections: scp, ovp, olp, otp ? dc ok indicator led with relay contacts ? 150% (180w) peak load capacity ? built-in active pfc,pf>0,95 ? high effciency up to 92.5% ac/dc converter pdr-1 rev.: 0/2016 www.recom-power.com basic characteristics parameter condition min. typ. max. input voltage range 85vac 264vac absolute maximum input voltage max. 3s 300vac 375vdc input current 115vac, full load 230vac, full load 1.5a 0.65a return voltage immunity 12vout 24vout 48vout 18v 35v 65v inrush current 115vac, cold start 230vac, cold start 40a 60a no load power consumption 115vac 230vac 1.5w 1.2w 3w 3w input frequency range 47hz 63hz output voltage trimming +16.67% power factor 115vac 230vac 0.99 0.95 start-up time 115vac, full load 230vac, full load 500ms 250ms hold-up time 115vac, full load 230vac, full load 20ms 20ms 40ms 40ms ripple and noise (1) 0 - 70c -25c 12vout 100mvp-p 200mvp-p 0 - 70c -25c 24vout 120mvp-p 240mvp-p -25c - 70c 48vout 240mvp-p continued on next page specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) ul60950-1 certifed ul508 certifed iec/en60950-1 certifed description these din-rail mounted power supplies have a robust case, 4mm screw terminal connectors and use high reliability components to give a long, trouble-free life. the redin120 can be end mounted to save rail space or side mounted for use in low-profle cabinets. the units can deliver up to 150% start-up power and allow n+1 parallel operation to increase the continuous output current or for supply redundancy. relay contacts simplify dc ok monitoring. the redin120 series is designed for demanding commercial and industrial applications with ul508, ul60950, iec60950 cb report and ce (lvd + emc + rohs) certifcations. they come with a full 5-year warranty. selection guide part nom. input output output rated effciency number voltage range voltage adjustability current typ. 230vac full load [vac] [vdc] [vdc] [a] [%] REDIN120-12 100-240 12 12-14 8.33 89.5 redin120-24 100-240 24 24-28 5 91.5 redin120-48 100-240 48 48-56 2.5 92.5 e224736 120 watt din-rail power supply redin120 5 y e a r w a r r a n t y 5 notes: note1: measured at 20mhz bandwidth by using a 12 twisted pair-wire terminated with a 0.1f & 10f parallel capacitor.
continued on next page ac/dc converter pdr-2 rev.: 0/2016 www.recom-power.com effciency vs. load effciency vs. load power dissipation vs load power dissipation vs load power factor vs load over vin power factor vs load over vin input current vs load input current vs load specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series REDIN120-12 redin120-24 115vac 230vac 264vac efficiency [%] load current [a] 0 10 0 20 40 60 80 100 2 30 4 50 6 8 70 90 iin 115vac [a] iin 230vac [a] input current [a] load current [a] 0 0 0.2 0.6 1 1.4 2 1 3 0.4 4 5 0.8 6 7 8 1.2 115vac 230vac dissipated power [w] load current [a] 0 5 0 10 20 2 15 4 25 6 8 115vac 230vac power factor [%] load current [a] 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 1 4 5 6 7 8 115vac 230vac 264vac efficiency [%] load current [a] 10 0 1 2 3 5 4 0 20 40 60 80 100 30 50 70 90 115vac 230vac dissipated power [w] load current [a] 0 5 0 10 20 2 1 15 4 3 5 25 iin 115vac [a] iin 230vac [a] input current [a] load current [a] 0 0 0.2 0.6 1 1.4 2 1 3 0.4 4 5 0.8 1.2 115vac 230vac power factor [%] load current [a] 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 1 4 5
regulation parameter condition value output accuracy 0.25% typ. / 1% max. line regulation 0.1% typ. / 0.5% max. load regulation 0% to 100% load 0.25% typ. / 1.0% max. transient response 100hz & 1khz, 50% duty 1% typ. / 5% max. ac/dc converter pdr-3 rev.: 0/2016 www.recom-power.com effciency vs. load power dissipation vs load power factor vs load over vin input current vs load specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) protection parameter condition value input fuse internal t5a, slow blow type short circuit protection (scp) hiccup mode (current limit) over voltage protection (ovp) 12vout 24vout 48vout 15-18vdc, hiccup mode 29-33vdc, hiccup mode 58-65vdc, hiccup mode over voltage category (ovc) ovc ii over load protection (olp) constant power (current limit) over temperature protection (otp) 1005c, detect on heat-sink of power transistor; shut down o/p, auto recovery after temperature goes down power ok led on (green) off (red) relay contact rating vout up to 90% of rated vout vout down to 80% of rated vout max. 30v/1a or 60v/0.3 or 30vac/0.3a resitive load continued on next page redin120 series redin120-48 115vac 230vac 264vac efficiency [%] load current [a] 40 30 20 10 0 0 0.5 1 1.5 2 2.5 50 60 70 80 100 90 115vac 230vac dissipated power [w] load current [a] 0 5 0 10 20 0.5 15 1 1.5 25 2 2.5 115vac 230vac power factor [%] load current [a] 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.5 1 1.5 2 2.5 iin 115vac [a] iin 230vac [a] input current [a] load current [a] 0 0 0.2 0.6 1 1.4 0.5 1 0.4 1.5 0.8 2 2.5 1.2
isolation voltage i/p to o/p i/p to pe o/p to pe 3.0kvac / 1minute 2.5kvac / 1minute 0.5kvac / 1minute isolation resistance 10m w min. leakage current i/p to o/p i/p to pe, 240vac 50hz 0.1ma typ. / 0.25ma max. 1.0ma max. ac/dc converter pdr-4 rev.: 0/2016 www.recom-power.com specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series environmental parameter condition value operating temperature range with derating -25c to +70c temperature coeffcient 0.03%/c operating altitude 3000m operating humidity non-condensing 20% - 90% rh ip rating ip20 pollution degree (pd) pd2 shock 10-500hz 2g, 60min. vibration 10g /11ms, along x,y and z axis mtbf mil-hdbk-217f, full load, 25c 300 x 103 hours continued on next page derating graph overload capability -25 -20 -10 0 0 10 20 20 30 40 40 50 60 60 70 80 80 100 pout 115vac cont. pout 230vac cont. ambient temperature [c] output power [%] -25 60 80 70 100 100 y 0 x 60 40 20 0 -20 0 20 40 60 80 75 100 ambient temperature [c] output power [%] 100 iout [%] pout [%] time [s] vadj. 85 12v 24v 48v REDIN120-12 redin120-24 redin120-48 14v 28v 56v time (x) [s] pout (y) [%] 1 180 4 150 7 140 45 120
ac/dc converter pdr-5 rev.: 0/2016 www.recom-power.com specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series emc compliance report / condition standard / criterion information technology equipment - radio disturbance characteristics - limits and methods of measurement en55022, class b, 2010 information technology equipment - immunity characteristics - limits and methods of measurement en55024, class b, 2010 limitations on the amount of electromagnetic intererence allowed from digital and electronic devices 47 cfr fcc part 15, subpart b: 2014 methods of measurement of radio-noise emissions from low-voltage electrical and electronic equipment in the range of 9 khz to 40 ghz ansi c63.4: 2014 esd electrostatic discharge immunity test air 8kv, contact 4kv en61000-4-2, criteria b, 2009 radiated, radio-frequency, electromagnetic feld immunity test 3v/m en61000-4-3, criteria a, 2006 fast transient and burst immunity ac power port: l+n+pe 1kv en61000-4-4, criteria b, 2012 surge immunity ac power port l-n 1kv, l-pe + n-pe 2kv en61000-4-5, criteria b, 2014 immunity to conducted disturbances, induced by radio-frequency felds ac power port 3v en61000-4-6, criteria a, 2014 power magnetic field immunity 50hz, 1a/m en61000-4-8, criteria a, 2010 voltage dips and interruptions voltage dips >95% voltage dips 30% voltage interruptions >95% en61000-4-11, criteria b, 2004 en61000-4-11, criteria c, 2004 en61000-4-11, criteria c, 2004 limits of harmonic current emissions en61000-3-2, criteria a, 2014 voltage fluctuations & flicker en61000-3-3, clause 5: 2013 safety and certifications certifcate type report / file number standard information technology equipment, general requirements for safety e224736 ul60950-1, 2nd edition, 2014 csa c22.2 no. 60950-1-07, 2nd edition, 2014 industrial control equipment e470721 ul508, 17th edition, 2013 csa c22.2 no. 107.1-01, 3rd edition, 2011 information technology equipment - general requirments for safety sa1508106s 001 + sa1508106s 002 iec60950-1, 2nd edition 2005, +am1:2009 + am2:2013 en60950-1:2006, + a11:2009 + a1:2010 + a12:2011 + a2:2013 dimension and physical characteristics parameter type value material case cover aluminium nickel plated steel package dimension (lxwxh) without mounting clip 114.5 x 33.0 x 124.4mm package weight 590g typ. continued on next page
ac/dc converter www.recom-power.com pdr-6 rev.: 0/2016 specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series dc ok -v +v 10.3 28.4 114.5 41.5 46.1 10.6 124.0 55.0 127.9 42.2 56.9 27.2 8.5 33.0 43.0 vadj. dc ok led parallel use single use l n pe 124.4 terminals and wiring type screw connector solid wire 2.5-6mm 2 stranded wire 2.5-4mm 2 american wire gauge (awg) awg10-16 wire stripping length 8mm screwdriver (slotted / cross) 3.5mm recommended tightening torque 0.5nm-0.8nm tolerance: x.x 0.5mm x.xx 0.25mm dc ok -v +v 10.3 28.4 114.5 41.5 46.1 10.6 124.0 55.0 127.9 42.2 56.9 27.2 8.5 33.0 43.0 vadj. dc ok led parallel use single use l n pe 124.4 dimension drawing (mm)
installation and application ac/dc converter pdr-7 rev.: 0/2016 www.recom-power.com specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series 15mm leave 15mm gap between supplies 15mm minimum abstand 15mm vadj. dc ok led parallel use single use vadj. dc ok led parallel use single use vadj. dc ok led parallel use single use mounting multiple power supplies mounting ?click? 1 2 vadj. dc ok led parallel use single use releasing 1 2 vadj. dc ok led parallel use single use mounting instruction
parallel operation application circuit ac/dc converter www.recom-power.com pdr-8 rev.: 0/2016 specifcations (measured @ t a = 25c, rated vin, rated load and after warm up) redin120 series the product information and specifcations are subject to change without prior notice. recom products are not authorized for use in safety-critical applications (such as life support) without recoms explicit written consent. a safety-critical application is defned as an application where a failure of a recom product may reasonably be expected to endanger or cause loss of life, infict bodily harm or damage property. the buyer shall indemnify and hold harmless recom, its affliated companies and its representatives against any damage claims in connection with the unauthorized use of recom products in such safety-critical applications. packagking information parameter type value packaging dimension (lxwxh) cardboard box 140.0 x 50.0 x 142.0mm packaging quantity cardboard box 1pcs. storage temperature range -40c to +85c storage humidity 5% - 95% rh l1 l2 l3 n pe +v -v dc ok +v -v dc ok +v -v dc ok dc ok ~ + - ~ ~ l n pe ~ ~ ~ + + + + - - - - load single operation: 1) make sure that the front panel switch is set to single use. 2) the output voltage can be increased by trim pot to compensate any cable losses. parallel operation: 1) make sure that the front panel switch is set to single use on each power supply. 2) adjust each power supply to the exact same output voltage with same load and cooling conditions. 3) set the front panel switches to parallel use. use the same wire length for each power supply (star connection) and energize all units at the same time to avoid triggering overload protection. derate the maximum output power to 90% of nominal ratings. for operation with more than three power supplies in parallel or series operation, please contact recom technical support for advice. power stage led l t5a n e -v dc ok vadj. single / parallel +v relay output filter protection input filter output voltage regulation ovp shut- down otp shut- down ocp limit


▲Up To Search▲   

 
Price & Availability of REDIN120-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X